Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant

$24.00
Size:
Packaging:
Quantity
In Stock — ready to ship from our Taylor, TX warehouse Order by Mon-Thu 1 PM CT / Fri 12 PM CT — ships in 1–2 business days If it’s listed, it’s on our shelf. No backorders, no 4-week lead times. Why
Temporarily unavailable This item isn’t ready to ship right now. Call 512-365-6838 for restock timing.
  • No hazmat fees from us — you pay the carrier’s shipping rate, at cost
  • Gallon+ sizes ship as DOT-regulated hazmat, so carrier freight runs higher — how shipping works
  • Drums, totes & pails ship LTL freight — liftgate delivery available
  • PO / Net 30 for approved businesses · tax-exempt ordering supported
Request COA TDS ↗
Customers Also Use

Customers who purchased Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant also bought:

CAS: 57-55-6 C3H8O2
CAS: 64-19-7 C2H4O2
Ammonium Hydroxide 29% ACS Grade
From $29.70
CAS: 1336-21-6 H5NO
Your selection

1 Quart · 1 Quart

SKU EG35-OAT-Q01

$24.00
Quantity
In Stock — ready to ship from our Taylor, TX warehouse Order by Mon-Thu 1 PM CT / Fri 12 PM CT — ships in 1–2 business days If it’s listed, it’s on our shelf. No backorders, no 4-week lead times. Why
Temporarily unavailable This item isn’t ready to ship right now. Call 512-365-6838 for restock timing.
  • No hazmat fees from us — you pay the carrier’s shipping rate, at cost
Customers Also Use

Customers who purchased Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant also bought:

CAS: 57-55-6 C3H8O2
CAS: 64-19-7 C2H4O2
Ammonium Hydroxide 29% ACS Grade
From $29.70
CAS: 1336-21-6 H5NO

Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant

$24.00

Product quick facts

CAS 107-21-1C2H6O2

Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant (CAS 107-21-1) is a 35% Inhibited-grade with molecular formula C2H6O2 and a molecular weight of 62.07 (ethylene glycol) g/mol. Alliance Chemical supplies this product in 7 sizes from 1 Quart to 330 Gallon with 1-2 business day shipping from Taylor, TX on in-stock orders, plus SDS and lot-specific Certificate of Analysis.

  • Pack sizes 7 sizes (1 Quart to 330 Gallon)
  • Purity / spec 35% Inhibited
  • Lead time In-stock orders placed by Mon-Thu 1 PM CT / Fri 12 PM CT typically ship within 1-2 business days.
  • SDS / COA Download SDS; lot-specific COA available on request.
  • Regional availability View state-by-state shipping pages (Top lanes: Texas, California).

Quick Answer

What is Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant used for, and what should buyers verify before ordering?

Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant is supplied at 35% in Inhibited grade . Buyers should confirm pack size, grade, SDS, COA needs, and freight requirements before purchase.

  • Assay: 35%
  • Grade: Inhibited
  • Documents: SDS and lot-specific COA support
  • Shipping: UPS for small packs; LTL/FTL for pails, drums, totes, and bulk orders

Commercial Fulfillment Snapshot

Buy Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant with faster decisions and fewer back-and-forth emails.

In-stock orders placed before 1:00 PM CT (Mon-Thu) and before 12:00 PM CT (Fri) typically ship within 1-2 business days. Order online 24/7.

Technical Documents

Live, always-current docs · lot-specific COA issued per shipment batch.

Who Buys This
  • Data center facility teams
  • Cooling system service contractors
  • HVAC and mechanical firms
  • Industrial maintenance departments
Purity / Grade Guide
  • Data center coolant applications
  • Inhibited ethylene glycol blend
  • OAT-908 additive included
  • COA and SDS included
Pack Sizes
  • 1 Quart: lab & small jobs
  • 1 Gallon: shop & maintenance
  • 5 Gallon: production & regular use
  • 15 Gallon: mid-volume operations
  • 55 Gallon: bulk drum
  • 275 Gallon: high-volume tote
  • 330 Gallon: max-volume tote
Small Packs: UPS Ground nationwide for pints, quarts, and gallons.
LTL / FTL: ABF, SEFL, Saia, XPO, and partner carriers for pails, drums, totes, and full truckloads.
Support: Email or call for freight options, hazardous-material routing, and lead-time confirmation.

Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant

Premium 35% v/v inhibited ethylene glycol coolant engineered for data centers, hyperscale direct-liquid cooling (DLC) loops, edge-compute thermal management, HVAC chillers, and industrial closed-loop heat-transfer systems. Pre-blended at 35% v/v ethylene glycol in deionized water with the OAT-908 hybrid corrosion-inhibitor package. Conforms to ASTM D3306 industrial coolant corrosion limits. 5+ year closed-loop service life under design conditions.

What is OAT-908?

OAT-908 is a hybrid Organic Acid Technology (OAT) corrosion-inhibitor package combining aliphatic organic acids with selective inorganic synergists (sodium nitrite, sodium molybdate, sodium benzoate) for simultaneous protection of copper, brass, mild steel, cast iron, aluminum, and lead-tin solder in a single fluid. Reduces silicate and phosphate fouling vs. legacy IAT and HOAT formulations.

Climate fit: West Texas, the Texas / Oklahoma / New Mexico belt, the Front Range (Denver, Albuquerque, Salt Lake City), and inland Mid-Atlantic / Southeast data-center sites that occasionally drop into the single digits Fahrenheit. Corresponds to ASHRAE Climate Zones 4 - 5 design conditions.

Performance

Engineered for the same closed-loop applications as premium industrial inhibited ethylene glycol coolants — chilled-water and condenser-water loops, DLC and rear-door heat exchangers, HVAC chiller systems, hydronic process cooling, and freeze / burst protection. Conforms to ASTM D3306 industrial coolant corrosion limits across the same six-metal ASTM D1384 coupon stack used to benchmark long-running inhibited glycol formulations.

Why data-center engineers specify this blend

  • Freeze protection to -20°C (-4°F) at the supplied 35/65 dilution — fits the climate-zone design conditions for the regions above
  • 5+ year closed-loop service life with annual fluid analysis (reserve alkalinity, pH, refractive index)
  • ASTM D3306 conformance across the full ASTM D1384 six-metal coupon stack
  • Hybrid OAT inhibitor reduces heat-exchanger fouling vs. silicate/phosphate IAT formulations
  • Elastomer-compatible with NBR (Buna-N), EPDM, FKM (Viton), HNBR, VMQ silicone, neoprene (CR), and CSM (Hypalon)
  • Made in the USA — blended at our Taylor, Texas facility under documented batch-control procedures with lot-specific Certificate of Analysis
  • Non-DOT-regulated — ships standard freight without hazmat surcharge

Typical specifications (35/65 blend)

Property Typical Value Method
Specific Gravity at 20°C 1.046 – 1.050 ASTM D1298
pH (as supplied) 8.5 – 10.0 ASTM D1287
Reserve Alkalinity 7 – 10 mL 0.1 N HCl ASTM D1121
Freeze Point ≤ -20°C (-4°F) ASTM D1177
Refractive Index at 20°C 1.358 – 1.362 ASTM D1747
Viscosity at 40°C 1.7 – 2.3 cP ASTM D445
Thermal Conductivity at 50°C 0.40 – 0.44 W/m·K ASHRAE 2017 ch.31
Specific Heat at 20°C 0.89 Btu/lb·°F (3.72 kJ/kg·K) ASHRAE 2017 ch.31

Documentation & lot traceability

  • Technical Data Sheet (TDS) — available in the Product Documents tab
  • Safety Data Sheet (SDS) — available in the Product Documents tab
  • Certificate of Analysis (COA) — lot-specific, issued with every shipment

Pack sizes

Available in 1 Quart, 1 Gallon, 5 Gallon pail, 15 Gallon HDPE drum, 55 Gallon HDPE drum, 4 x 55 Gallon Drum pallet, 275 Gallon IBC tote, and 330 Gallon IBC tote — from sample / bench-test quantities up to bulk pallet and IBC orders. For tanker-volume orders please contact sales@alliancechemical.com directly.

Maintenance & make-up

Use only deionized or distilled water (less than 50 µS/cm conductivity, < 25 ppm chloride, < 25 ppm sulfate) for top-up and make-up. Annual fluid analysis is recommended; replace fluid when reserve alkalinity falls below 5.0 mL or pH drops below 7.0.

Pet-safety note: ethylene glycol is highly toxic to dogs, cats, and wildlife if ingested. Clean up spills immediately and store containers out of reach of animals. See the SDS for full hazard, first-aid, and disposal guidance.

Property Value
Molecular Weight 62.07 (ethylene glycol component)
Formula C2H6O2 / H2O blend with OAT corrosion inhibitor
Assay 35%
Grade Inhibited
Form Liquid
Solubility Miscible in water
Appearance Clear, colorless liquid (fluorescent dye available on request)
Industry Data Center, Hyperscale, HVAC, Industrial. Mid-continent and mountain-west outdoor cooling. ASHRAE Climate Zones 4-5.

Frequently Asked Questions About Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant

What is Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant and what is its chemical formula?
Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant is a chemical compound with the molecular formula C2H6O2, registered under CAS Number 107-21-1 by the Chemical Abstracts Service (PubChem), with a molecular weight of 62.07 (ethylene glycol) g/mol. Alliance Chemical supplies Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant in Inhibited grade for laboratory, industrial, and commercial applications.
What grade and purity of Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant does Alliance Chemical offer?
Alliance Chemical offers Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant in Inhibited grade with a purity assay of 35%. A lot-specific Certificate of Analysis (COA) is available for every shipment, and each product ships with a Safety Data Sheet (SDS) prepared in accordance with OSHA Hazard Communication Standard 29 CFR 1910.1200 and GHS Revision 7. Download SDS.
What are common industrial applications of Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant?
Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant has applications in laboratory research, manufacturing, and industrial processing.Alliance Chemical provides the documentation and quality certifications required for use in regulated environments.
What are the hazards of Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant and where do I find handling guidance?
Per its GHS classification (SDS Section 2), Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant carries the signal word Warning and the following hazard statements: H302 (Harmful if swallowed). Product-specific first aid, fire-fighting, spill response, handling, storage, exposure controls/PPE, and disposal guidance are in SDS Sections 4-8 and 13 — always consult the SDS before use. Download the SDS.
How must Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant waste be disposed?
Disposal per RCRA (40 CFR 261-265): the waste characterization under 40 CFR 261 is the generator's responsibility — see SDS Section 13 for product-specific guidance. Generator requirements: EPA ID number required if >100 kg/month (40 CFR 262.12). Use an EPA-permitted Treatment, Storage, Disposal Facility (TSDF). Never discharge to sewer without POTW written approval (40 CFR 403). Container disposal: triple rinse (40 CFR 261.7), offer for reconditioning/recycling. State regulations may be more stringent — check with your local environmental agency.
Does Alliance Chemical provide an SDS and COA for Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant?
Yes. Alliance Chemical provides a Safety Data Sheet (SDS) and Certificate of Analysis (COA) for every lot of Inhibited Ethylene Glycol 35/65 with OAT-908 — Data Center Coolant. The SDS is prepared in accordance with OSHA Hazard Communication Standard 29 CFR 1910.1200 and the Globally Harmonized System (GHS) Revision 7, covering all 16 required sections including hazard identification, first aid measures, firefighting measures, handling and storage, exposure controls, and regulatory information. The SDS is available for download directly from this product page. COAs are available upon request by contacting Alliance Chemical at 512-365-6838.