Inhibited Propylene Glycol 40/60 with OAT Corrosion Inhibitor is a ready-to-use closed-loop heat-transfer fluid blended at our Taylor, TX facility: 40% propylene glycol by weight in deionized water with a nitrite-containing hybrid organic-acid (OAT) corrosion inhibitor package. The package combines sodium nitrite, sodium molybdate, sodium benzoate and triethanolamine with organic-acid inhibitors, formulated for steel, cast iron, copper, brass and solder.
Applications
- HVAC chillers & hydronic heating loops
- Data center liquid cooling (secondary loop)
- Food & beverage processing chillers (secondary loop, indirect)
- Automated beverage dispensing equipment
- Glycol-charged process cooling
- Freeze protection for outdoor and exposed piping
Specifications
-
Composition: propylene glycol 39.5–40.5% by weight (w/w); corrosion inhibitor package 1.8–2.2%; deionized water balance
-
CAS: 57-55-6 (PG), 7732-18-5 (Water); product is a mixture
-
Nitrite (as NO2): 960 ppm min.
-
Specific gravity (20°C): 1.035–1.043 (calculated)
-
Density: approx. 1.04 g/mL (8.7 lb/gal)
-
pH: reported on the lot Certificate of Analysis (typically 7.0–9.0)
-
Reserve alkalinity: reported on the lot COA
-
Freeze point: approx. -6 °F (-21 °C); specification -5 °F (-20.6 °C) max
-
Boiling point: approx. 219 °F (104 °C)
-
Appearance: clear, colorless to pale yellow liquid; not dyed (dye available on request)
Documentation
- Lot-specific Certificate of Analysis (COA) on request
- Branded Technical Data Sheet (TDS) — AC-TDS-PG40-OAT
- Safety Data Sheet (SDS) — AC-PG40-OAT-001
Handling
Not classified as hazardous under GHS and not regulated for transport by DOT. Contains sodium nitrite: install as a fresh fill after draining and flushing, do not mix with phosphate-, silicate- or nitrite-free coolants, keep away from strong acids, and avoid galvanized (zinc) surfaces. Refer to the Safety Data Sheet (SDS) for full handling information.
Available sizes: 1 quart through 330-gallon IBC tote. Bulk tanker quoted on request.
Not for: direct or incidental food contact, potable water, open recirculation, automotive crankcase, or single-pass cooling.