Chemicals for semiconductor and electronics manufacturing

ACS reagent acids, oxidizers, solvents and low-ion glycols for wafer cleaning, etching, resist stripping and tool cooling.

Every size listed is priced and sold online, with no minimum. Quotes are for multi-unit, bulk and recurring supply. Or call 512-365-6838.

Automated placement head above panels of printed circuit boards

Photo: Louis Reed on Unsplash

Where the chemistry goes

Four steps of a wet process, from the first clean to the chiller loop. Each product title states its grade.

  1. Step 1 Wafer cleaning

    Quartz bath with a wafer cassette, cut away

    The RCA sequence removes particles with ammonia and peroxide (SC-1), then metal ions with hydrochloric acid and peroxide (SC-2). A sulfuric acid and peroxide strip lifts heavy organics.

  2. Step 2 Etching

    Process bath, cut away

    Acid mixtures etch silicon, oxides and nitride at controlled rates. Hot phosphoric acid takes silicon nitride selectively; fluoride salts open oxide layers.

  3. Step 3 Solvent cleaning and drying

    Solvent rinse bath, cut away

    Solvents strip photoresist and flux and leave surfaces dry. Isopropyl alcohol is the usual last rinse because it carries water off and evaporates clean.

  4. Step 4 Rinse water and tool cooling

    Shell-and-tube heat exchanger, cut away

    Deionized water dilutes and rinses between steps. Tool chillers run a glycol loop where low conductivity and low ion content protect the equipment.

Technical notes

Reference notes on the specifications, grade choices, regulations and buying mistakes that matter when you source wet-process chemicals for a fab, a pilot line or an electronics lab.

Key specifications

Specification Why it matters
Trace metals (ppb) Sodium, iron, copper and other metal ions deposit on the wafer and shift the electrical behavior of junctions and gate oxides. Compare the metals on the lot's COA with your process limit, not with the grade name.
Particle count (per mL) Particles in a clean or rinse chemistry land on the wafer as defects that block patterning or bridge features. ACS reagent specifications do not set a particle limit, so ask before you rely on one.
Assay / purity (%) Etch and clean rates depend on concentration, so a lot that runs high or low changes the result at the same time and temperature. A tight assay range keeps recipe timing stable from lot to lot.
Moisture content Concentrated acids and dry solvents pick up water from the air once opened. Water dilutes an etch mix and slows solvent drying, so keep containers sealed.
Container material The container touches the chemical for its whole shelf life and can add metals, particles or plastic additives. HDPE and fluoropolymer containers are the usual choice for high-purity acids and solvents.

Industry overview

Semiconductor and electronics manufacturing runs on wet chemistry. A wafer passes through cleaning, etching, resist stripping and rinsing steps many times, and each step depends on acids, oxidizers and solvents of known purity. The RCA clean uses ammonium hydroxide and hydrogen peroxide (SC-1) to lift particles, then hydrochloric acid and hydrogen peroxide (SC-2) to remove metal ions. A sulfuric acid and peroxide mix, often called piranha, strips heavy organics. Hot phosphoric acid etches silicon nitride, and acetone removes photoresist and flux. Isopropyl alcohol is the usual final rinse because it carries water off and evaporates clean.

Around the wet bench, deionized water dilutes and rinses, and tool chillers run on deionized water, water and glycol mixes or fluorinated fluids, as the tool maker specifies. Chemical purity shows up directly in defect density and yield. Production front-end steps at advanced nodes typically specify SEMI-grade chemicals with metals in parts per trillion. ACS reagent grade fits R&D, process development, pilot lines, failure analysis labs and many back-end and board-level steps.

Why grade matters

Grade sets the impurity ceiling, and the gap between grades is mostly about metals and particles. ACS reagent specifications set metal limits at or below the part-per-million level, while the SEMI grades used for advanced front-end work set them in parts per billion or parts per trillion. ACS reagent isopropyl alcohol 99.9% is a good fit for equipment wipe-downs, lab-scale process development and board cleaning, but it can leave metal contamination in a critical front-end clean. In tool chillers, semiconductor-grade ethylene glycol is uninhibited, with no dyes or inhibitor salts, which keeps loop conductivity down. Automotive antifreeze adds dyes, silicates and other inhibitors you do not want in a tool loop. Whatever the grade, compare the COA for the lot with your process window before the chemical reaches the cleanroom.

Regulations to know

OSHA permissible exposure limits for solvents and corrosive acid mists drive the design of wet bench exhaust and cleanroom ventilation, and the OSHA Hazard Communication Standard requires a current SDS for every chemical on site. Ammonium bifluoride and other fluoride etchants call for hydrofluoric acid precautions, including calcium gluconate first aid. Chemicals in US commerce must be on the TSCA inventory or covered by an exemption. Wastewater from wafer and component plants falls under the Electrical and Electronic Components effluent guidelines (40 CFR Part 469), which together with local pretreatment permits limit what you can discharge. If you ship finished components to the European Union, REACH and RoHS restrict certain substances in the product itself. Confirm current limits with your EHS team, and find SDSs in our SDS library.

Common purchasing mistakes

  • Moving an ACS reagent acid into a front-end clean. A sulfuric acid and peroxide strip made with ACS reagent acid can leave enough metal on test wafers to fail a qualification run at a tight node. Check the lot's metals against the process limit first.
  • Ignoring the container. Drum linings, cap liners and how a container was cleaned all add metals and particles. Ask what the product ships in before you write it into a specification.
  • Leaving hygroscopic chemicals open. Isopropyl alcohol and concentrated sulfuric acid both pull water from humid air, which changes drying behavior and etch rates. Keep containers sealed and buy sizes you will use while fresh.
  • Putting antifreeze in a tool chiller. Inhibited automotive glycol raises loop conductivity and can foul small cooling passages. Use the glycol the tool maker specifies.

Shipped from Taylor, Texas

Most in-stock orders leave in one to two business days. Parcel or freight depends on what is in the box, not on who is buying, and every size listed is sold online.

UPS Ground Bottles, jugs and up to three pails
LTL freight Four or more pails, drums and totes, by liftgate truck on a pallet
  • UPS
  • ABF Freight
  • FedEx Freight
  • R+L Carriers
  • Saia
  • Southeastern Freight Lines
  • XPO

The carrier's hazmat fee is passed through at cost. See the shipping guide for how orders are packed and rated.

Questions buyers ask

Do you sell SEMI C-series grades?

No. Our highest-purity acids, oxidizers and solvents are ACS reagent grade, and the product title states the grade. ACS reagent grade is not made to SEMI parts-per-trillion metal limits, so it suits R&D, pilot lines and back-end work rather than critical front-end cleans.

What is an RCA clean?

A two-step wet clean: SC-1 (ammonium hydroxide, hydrogen peroxide and water) removes particles and organics, then SC-2 (hydrochloric acid, hydrogen peroxide and water) removes metal ions. Both are mixed fresh and used warm.

Can I buy single bottles for a lab line or a pilot tool?

Yes. Sizes run from small containers to totes, depending on the product, and every size listed is priced and sold online with no minimum. No account is needed.

Is semiconductor-grade ethylene glycol different from antifreeze glycol?

It is uninhibited high-purity glycol, so it carries no dyes, silicates or inhibitor salts. Check the COA against the ionic or conductivity limit your chiller maker sets; automotive antifreeze carries dyes and inhibitor packages you do not want in a tool loop.

Do you send a certificate of analysis?

A COA for the lot you receive is free on request, and safety data sheets for every product are in the SDS library.

Why does moisture content matter in etching acids and solvents?

Water dilutes an acid and changes its concentration, which speeds up or slows down the etch rate. In isopropyl alcohol, absorbed water slows drying and can leave water spots, so keep containers sealed between uses.

What containers suit high-purity acids and solvents?

High-density polyethylene (HDPE) and fluoropolymer (PFA or PTFE) containers are common because they add little metal to the contents. Stronger hydrogen peroxide is normally packed with a vented cap. Check the product page for the container each size ships in.

How does particle count affect wafer yield?

Particles in a cleaning or rinse chemistry deposit on the wafer, where they can block a lithography exposure, mask an etch or bridge two features. More particles per milliliter means more defects per wafer and lower yield.

How do trace metals affect semiconductor devices?

Metal ions such as sodium, iron and copper move into silicon and oxide layers and change their electrical behavior, causing leakage, threshold shifts and early failures. That is why front-end cleans specify metal limits in parts per billion or lower.

Is bottled deionized water the same as a fab's ultrapure water?

No. Fabs purify water on site and pipe it straight to the tools. Bottled deionized water suits lab dilution, pilot work and rinsing where your specification allows it, so compare the lot's specification with your requirement first.

Order today, or talk it through first

Every size listed on this page is priced and sold online. For drums and totes on a schedule, several delivery points or net 30 terms, send us your volumes and we will quote the product and the freight.

Call sales 512-365-6838

Monday to Thursday 8 am to 4 pm, Friday 8 am to noon, Central time