Hydro-cooled miners · Bitmain S19, S21, S23 Hyd

Coolant for Antminer Hydro Miners

For Bitmain Antminer Hydro: S21 XP Hyd, S21 XP+ Hyd, S21 / S21+ / S21e Hyd, S19 XP Hyd, S19 Pro Hyd, S23 Hyd. Blended and shipped from Taylor, Texas, with a certificate of analysis on every lot.

See the coolant Get a tote quote

01

The short answer

Quick answer

Antminer Hydro units run on antifreeze, pure water or deionized water. For antifreeze Bitmain specifies pH 7.0 to 9.0, and most Antminer Hydro fleets sit in ANTSPACE HK3 containers whose coolant table caps boron, silicon, phosphorus, molybdenum and calcium. For those sites we supply our nitrite-free inhibited ethylene glycol premix. Sites on third-party dry coolers can also run our nitrite-containing organic-acid premixes.

Row of hydro-cooled ASIC mining servers in a liquid-cooled rack with blue supply and red return coolant hoses on quick-connect fittings
02

What to order

The products that fit this spec, and what each one is for.

HK3 containers

Inhibited Ethylene Glycol 40/60, Nitrite-Free

Nitrite-free inhibitor with no silicate, borate or molybdate and only trace phosphate, so it stays inside the HK3 element caps. 40% ethylene glycol covers a Texas freeze.

Freeze point: about -25 °C (-13 °F) typical · Quart to 330-gallon tote · COA with every lot

Third-party dry coolers

Inhibited Ethylene Glycol 40/60 with OAT-908

40% ethylene glycol with a nitrite-containing hybrid organic-acid inhibitor, pH typically 7.0 to 9.0. For loops outside the HK3 element caps.

Freeze point: approx. -22 °C (-8 °F) typical; -21 °C (-6 °F) max, at 40 wt% ethylene glycol · Quart to 330-gallon tote · COA with every lot

Flush and make-up

Deionized Water ACS Reagent Grade

Conductivity under 1 µS/cm for flushing new piping and evaporative top-off.

Quart to 330-gallon tote · COA with every lot

Need a different concentration? We blend to the freeze point you specify, in pails, drums and 275- or 330-gallon totes.

03

What Bitmain requires

The coolant rules from the manufacturer's published documentation.

Coolant optionsAntifreeze, pure water or deionized water
pH by mediumAntifreeze 7.0 to 9.0; pure water 6.5 to 7.5; deionized water 8.5 to 9.5 (Bitmain manuals)
Inlet temperature20 to 50 °C; the unit will not start below 20 °C inlet
Flow and pressure8 to 10 L/min per miner, 3.5 bar max (S21 XP Hyd)
Container rulesIn ANTSPACE HK3 containers the coolant must also meet the HK3 table (see the HK3 page)

Source: Bitmain S21 XP Hyd and S19 XP Hyd specification pages (coolant pH by medium; container coolant rules in the ANTSPACE HK3 manual).

04

Spec check, line by line

Bitmain antifreeze requirements against our ethylene glycol premixes

Parameter Bitmain requirement What we supply Status
pH (antifreeze) 7.0 to 9.0 Nitrite-free premix: specification 8.0 to 9.5. Nitrite-containing organic-acid premixes: typically 7.0 to 9.0. Measured value on the lot COA Check COA
Reserve alkalinity ≥ 4 mL for organic-acid formulas (HK3 table) Measured per lot (ASTM D1121) and reported on request On request
Element caps in HK3 containers B, Si, P, Mo, Ca each < 20 mg/kg Nitrite-free premix: no borate, silicate or molybdate in the inhibitor, phosphate only as a trace. The nitrite-containing package includes a molybdate, so use the nitrite-free premix in HK3 containers Meets
Freeze protection Set by site; drain units in storage 40% EG premixes: about -22 to -25 °C. 50% EG premix: about -34 °C Meets

"Meets" rows are taken from our controlled specifications: the product technical data sheet and the deionized water specification we blend with. "On request" values are measured per lot and sent with your order when you ask.

05

Questions

What coolant does an Antminer S21 XP Hyd use?

Bitmain lists antifreeze, pure water or deionized water. For antifreeze the pH should be 7.0 to 9.0. Inlet temperature runs 20 to 50 °C at 8 to 10 L/min per miner, and pressure stays at or below 3.5 bar.

Water or antifreeze for a Texas hydro site?

Antifreeze, if the dry coolers or piping can see a freeze. In February 2021 Dallas-Fort Worth fell to about -19 °C (-2 °F). A 40% ethylene glycol premix protects to about -22 to -25 °C.

Which inhibitor is right for an ANTSPACE HK3?

The HK3 coolant table caps boron, silicon, phosphorus, molybdenum and calcium at 20 mg/kg each. Our nitrite-free premix has no borate, silicate or molybdate in its inhibitor and only a trace of phosphate, so it is the one we supply for HK3 containers.

How much coolant does each miner hold?

Very little; the fill is set by the container or dry-cooler loop. An HK3 container takes roughly 1.3 to 1.5 tonnes of coolant, about 1.2 to 1.4 totes of 275 gallons.

Can I mix different coolants?

No. Do not mix inhibitor chemistries. Drain, flush with deionized water and refill when you switch products.

Quote a fill

Tell us the site, the number of totes or the system volume, and the date the coolant has to be on site. We reply with pricing, freight and lead time.

Related: texas hydro mining coolant freeze protection · antspace hk3 coolant · bitdeer sealminer hydro coolant · whatsminer hydro coolant · glycol heat transfer fluid technical submittal

Bitmain, Antminer and ANTSPACE are trademarks of their respective owners. Alliance Chemical is not affiliated with or endorsed by Bitmain. Requirements are quoted from Bitmain's published specifications and manuals; confirm against your model's current manual and warranty terms before filling.