Arctic Assist 50/50

Category : Glycols

$18.85
Quantity
Size:
Variation:
$18.85

Arctic Assist 50/50

$18.85

Quick Answer

What is Arctic Assist 50/50 used for, and what should buyers verify before ordering?

Arctic Assist 50/50 is supplied at 50% in Technical grade . Buyers should confirm pack size, grade, SDS, COA needs, and freight requirements before purchase.

  • Assay: 50%
  • Grade: Technical
  • Documents: SDS and lot-specific COA support
  • Shipping: UPS for small packs; LTL/FTL for pails, drums, totes, and bulk orders

Commercial Fulfillment Snapshot

Buy Arctic Assist 50/50 with faster decisions and fewer back-and-forth emails.

Ships from Taylor, Texas. In-stock orders placed before 1:00 PM CT (Mon-Thu) and before 12:00 PM CT (Fri) typically ship within 1-2 business days. Order online 24/7.

Technical Documents

Lot-specific COA is issued per shipment batch.

Who Buys This
  • Automotive service shops
  • Fleet maintenance companies
  • Equipment rental businesses
  • Industrial cooling system operators
  • Marine & RV service centers
Purity / Grade Guide
  • Industrial & commercial applications
  • Verified purity, COA included
  • Suitable for equipment maintenance
  • Ready-to-use 50/50 formulation
Pack Sizes
  • 1 Quart: lab & small jobs
  • 1 Gallon: shop & maintenance
  • 5 Gallon: production & regular use
  • 15 Gallon: mid-volume operations
  • 55 Gallon: bulk drum
  • 275 Gallon: high-volume tote
  • 330 Gallon: max-volume tote
SDS / COA / TDS
  • UN 1268 Class 3 packaging
  • Complete SDS with every order
  • COA for quality verification
  • DOT compliant shipping labels
Small Packs: UPS Ground nationwide for pints, quarts, and gallons.
LTL / FTL: ABF, SEFL, Saia, XPO, and partner carriers for pails, drums, totes, and full truckloads.
Support: Email or call for freight options, hazardous-material routing, and lead-time confirmation.

Why Arctic Assist 50/50

Industrial and research buyers select Arctic Assist 50/50 Laboratory Grade when operations demand an exact 50 percent concentration with moderate organic solvent solubility and a confirmed flash point of 62. Supplying a pre-mixed liquid eliminates the variables introduced by on-site water blending, ensuring a locked point on the freeze protection curve that remains consistent across closed-loop systems. Because it arrives as a pre-diluted, low-viscosity fluid, facilities avoid the calculation errors that can compromise thermal efficiency or damage sensitive equipment during extreme temperature swings. The highly visible pink dyed liquid provides an immediate visual confirmation of fluid levels, system integrity, and active flow within complex piping networks. Based on the C12H26 molecular formula (CAS 64742-47-8), this laboratory-grade specification guarantees strict adherence to analytical parameters required by highly regulated testing environments.

System engineers must evaluate fluid chemistry to determine the exact need for inhibited or uninhibited closed-loop protection. While inhibited fluids contain added corrosion deterrents for long-term multi-metal protection, this specific uninhibited formulation provides a pure baseline fluid free of heavy additives, making it highly applicable for targeted environmental research where additive interference must be avoided.

Best Applications for This Grade

  • Commonly applied in specialized industrial heat transfer loops where the exact 50 percent concentration aligns precisely with the targeted freeze protection curve and operational thermal requirements.
  • Commonly applied in environmental laboratory settings that require a stable C12H26 formulation with a specific flash point of 62 for calibrating flow meters and verifying diagnostic instrumentation.
  • Commonly applied in research testing rigs where a low-viscosity, pink dyed liquid is necessary to trace fluid dynamics, monitor circulation rates, and quickly identify microscopic leaks at system joints.
  • Commonly applied in heavy-duty automotive shop testing apparatuses that require an uninhibited, strictly non-commercially suitable industrial liquid to simulate thermal exchange without introducing complex corrosion inhibitors that might skew analytical results.

When to Choose a Different Grade

  • If your facility requires a customized fluid ratio to achieve a specific, deeper freeze protection curve than a 50 percent mix provides, you should source the 100 percent concentration of Arctic Assist for precise on-site dilution.
  • If the operational environment demands active multi-metal corrosion protection in a mixed-metal closed loop over an extended timeline, you will need to specify a heavily inhibited version of Arctic Assist rather than this baseline uninhibited formula.
  • If the application involves any proximity to food processing, beverage production, or pharmaceutical lines, you must bypass this toxic laboratory specification entirely and select a verified USP-grade fluid designated explicitly for potential incidental food contact.
Property Value
Molecular Weight 170.33
Formula C12H26
Assay 50%
Grade Technical
Flash Point 62°C (143.6°F)
Form Liquid
Solubility Moderate organic solvent solubility
Appearance pink dyed liquid, low viscosity
Melting Point -9°C (15.8°F)
Boiling Point 165°C (329°F)
Specific Gravity 1.045
Industry Industrial & Manufacturing, Lab & Research, Water & Environmental

Frequently Asked Questions About Arctic Assist 50/50

What is Arctic Assist 50/50 and what is its chemical formula?
Arctic Assist 50/50 is a chemical compound with the molecular formula C12H26, registered under CAS Number 64742-47-8 by the Chemical Abstracts Service (PubChem), with a molecular weight of 170.33 g/mol. Alliance Chemical supplies Arctic Assist 50/50 in Technical grade for laboratory, industrial, and commercial applications.
What are the physical properties of Arctic Assist 50/50?
According to the NIOSH Pocket Guide to Chemical Hazards, Arctic Assist 50/50 is supplied as a pink dyed liquid, low viscosity. It has a melting point of -9°C (15.8°F)°C, a boiling point of 165°C (329°F)°C, a flash point of 62°C (143.6°F). The specific gravity is 1.045 relative to water. Solubility: Moderate organic solvent solubility.
What grade and purity of Arctic Assist 50/50 does Alliance Chemical offer?
Alliance Chemical offers Arctic Assist 50/50 in Technical grade with a purity assay of 50%. Every lot ships with a Certificate of Analysis (COA) and Safety Data Sheet (SDS) prepared in accordance with OSHA Hazard Communication Standard 29 CFR 1910.1200 and GHS Revision 7. Download SDS.
What are common industrial applications of Arctic Assist 50/50?
Arctic Assist 50/50 serves a wide range of sectors, including Industrial & Manufacturing, Lab & Research, and Water & Environmental.Alliance Chemical provides the documentation and quality certifications required for use in regulated environments.
What PPE is required when handling Arctic Assist 50/50?
OSHA-mandated PPE per 29 CFR 1910.132-138:Nitrile gloves (8+ mil), safety goggles, flame-resistant clothing, grounded footwear, closed-toe chemical-resistant footwear. Respiratory protection (organic vapor cartridge) required in areas exceeding PEL/TLV per 29 CFR 1910.134. Emergency eyewash station and safety shower must be accessible within 10 seconds per ANSI Z358.1. Consult the SDS available from Alliance Chemical for complete PPE requirements.
What are the storage requirements for Arctic Assist 50/50?
Store perOSHA 29 CFR 1910.106: Approved flammable storage cabinet, maximum 60 gallons per cabinet, grounding/bonding required. Temperature range:15-25°C. Segregate from:oxidizers, ignition sources. Maximum storage:2-3 years unopened.
What is the emergency spill procedure for Arctic Assist 50/50?
Emergency response per EPA SPCC (40 CFR 112) and OSHA 29 CFR 1910.120: (1) Alert personnel, evacuate area to 100 feet. (2) Eliminate ignition sources if flammable. (3) Don PPE per SDS Section 8. (4) Stop leak if safe; use emergency shutoffs. (5) Contain with non-combustible absorbent materials, dike with sand/earth. (6)Absorb with vermiculite or commercial spill kits. (7) Collect in DOT-approved containers, label as hazardous waste. Check 40 CFR 302.4 for Reportable Quantity. Emergency: Chemtel 1-800-255-3924 (24/7). Non-emergency: Alliance Chemical 512-365-6838.
What is the DOT shipping classification for Arctic Assist 50/50?
DOT Classification per 49 CFR 172.101:UN1993 (Flammable Liquid, N.O.S.), Hazard Class3 (Flammable), Packing GroupII/III. Requires: Hazmat shipping papers (49 CFR 172.200), UN specification packaging (49 CFR 173), hazmat labels (172.400). Alliance Chemical ships all orders in DOT-compliant packaging with proper documentation.
How must Arctic Assist 50/50 waste be disposed?
Disposal per RCRA (40 CFR 261-265):Characteristic waste D001 (Ignitable, flash point <60°C). Generator requirements: EPA ID number required if >100 kg/month (40 CFR 262.12). Use EPA-permitted Treatment, Storage, Disposal Facility (TSDF). Never discharge to sewer without POTW written approval (40 CFR 403). Container disposal: Triple rinse (40 CFR 261.7), offer for reconditioning/recycling. State regulations may be more stringent — check with your local environmental agency. Consult the Alliance Chemical SDS for product-specific disposal guidance.
Does Alliance Chemical provide an SDS and COA for Arctic Assist 50/50?
Yes. Alliance Chemical provides a Safety Data Sheet (SDS) and Certificate of Analysis (COA) for every lot of Arctic Assist 50/50. The SDS is prepared in accordance with OSHA Hazard Communication Standard 29 CFR 1910.1200 and the Globally Harmonized System (GHS) Revision 7, covering all 16 required sections including hazard identification, first aid measures, firefighting measures, handling and storage, exposure controls, and regulatory information. The SDS is available for download directly from this product page. COAs are available upon request by contacting Alliance Chemical at 512-365-6838.