Perchloroethylene (PCE, PERC)

$95.00
Size:
Pack & price:
  • $26.40
    Delivery every
    $25.08
  • $50.10
    Delivery every
    $47.60
  • $95.00
    Delivery every
    $90.25
  • $179.00
    Delivery every
    $170.05
  • $95.00
    Delivery every
    $90.25
  • $179.00
    Delivery every
    $170.05
  • $192.50
    Delivery every
    $182.88
  • $4,700.00
    Delivery every
    $4,465.00
  • $230.00
    Delivery every
    $218.50
  • $850.00
    Delivery every
    $807.50
  • $6,900.00
    Delivery every
    $6,555.00
  • $1,900.00
    Delivery every
    $1,805.00
  • $7,068.95
    Delivery every
    $6,715.50
Ships UPS Ground
Quantity
In Stock — ready to ship from our Taylor, TX warehouse Order by Mon-Thu 2 PM CT / Fri 12 PM CT — ships in 1–2 business days If it’s listed, it’s on our shelf. No backorders, no 4-week lead times. Why
Temporarily unavailable This item isn’t ready to ship right now. Call 512-365-6838 for restock timing.
  • No hazmat fees from us — you pay the carrier’s shipping rate, at cost
  • Gallon+ sizes ship as DOT-regulated hazmat, so carrier freight runs higher — how shipping works
  • Drums, totes & pails ship LTL freight — liftgate delivery available
  • PO / Net 30 for approved businesses · tax-exempt ordering supported

Need a different spec?

Perchloroethylene (PCE, PERC) Current
Perchloroethylene ACS Grade From $32.18
Customers Also Use

Customers who purchased Perchloroethylene (PCE, PERC) also bought:

Popular Combo
A-A-59601E Type III Technical Grade
From $21.21
CAS: 64742-47-8 Mixture
Popular Combo
Proprietary Blend
Popular Combo
Petroleum Ether Technical Grade
From $39.60
CAS: 8032-32-4 C5-C12 Hydrocarbons
Popular Combo
Hexane Technical Grade
From $25.35
CAS: 110-54-3 C6H14
Your selection

1 Gallon Can

SKU A6-YQMP-ZELE

$95.00
Quantity
In Stock — ready to ship from our Taylor, TX warehouse Order by Mon-Thu 2 PM CT / Fri 12 PM CT — ships in 1–2 business days If it’s listed, it’s on our shelf. No backorders, no 4-week lead times. Why
Temporarily unavailable This item isn’t ready to ship right now. Call 512-365-6838 for restock timing.
  • No hazmat fees from us — you pay the carrier’s shipping rate, at cost
Customers Also Use

Customers who purchased Perchloroethylene (PCE, PERC) also bought:

Popular Combo
A-A-59601E Type III Technical Grade
From $21.21
CAS: 64742-47-8 Mixture
Popular Combo
Proprietary Blend
Popular Combo
Petroleum Ether Technical Grade
From $39.60
CAS: 8032-32-4 C5-C12 Hydrocarbons
Popular Combo
Hexane Technical Grade
From $25.35
CAS: 110-54-3 C6H14

Perchloroethylene (PCE, PERC)

$95.00

Product quick facts

CAS 127-18-4C2Cl4UN1897

Perchloroethylene (PCE, PERC) (CAS 127-18-4) is a 100% Technical Grade liquid with molecular formula C2Cl4 and a molecular weight of 165.8 g/mol, for industrial and manufacturing applications. It has a flash point of No flash point in conventional closed tester., and it ships as DOT Hazard Class 6.1. Alliance Chemical supplies this product in 4 container sizes from 1 Quart to 55 Gallon (13 pack options) with 1-2 business day shipping from Taylor, TX on in-stock orders, plus SDS and lot-specific Certificate of Analysis.

  • Pack sizes 4 container sizes (1 Quart to 55 Gallon) · 13 pack options
  • Purity / spec 100% Technical Grade
  • Lead time In-stock orders placed by Mon-Thu 2 PM CT / Fri 12 PM CT typically ship within 1-2 business days.
  • Regional availability View state-by-state shipping pages

Quick Answer

What is Perchloroethylene (PCE, PERC) used for, and what should buyers verify before ordering?

Perchloroethylene (PCE, PERC) is supplied at 100% in Technical Grade with UN1897, DOT Class 6.1 . Buyers should confirm pack size, grade, SDS, COA needs, and freight requirements before purchase.

  • Assay: 100%
  • Grade: Technical Grade
  • UN number: UN1897
  • DOT class: 6.1

Technical Documents

Live, always-current documents. Need the Certificate of Analysis for your lot? Just ask, no charge.

Who Buys This
Dry cleaning operators, metal fabrication and machine shops running vapor degreasers or parts washers, and chemical manufacturers using PCE as a synthesis intermediate are the primary buyers.
Purity / Grade Guide
Technical grade perchloroethylene is specified for production-scale solvent applications — degreasing, dry cleaning, and chemical processing — where industrial solvent performance matters more than analytical-purity certification. Review the TDS to confirm the specification meets your process requirements.
Pack Sizes
Quart and gallon sizes serve lab use, small parts washers, and spot-cleaning operations. Five-gallon pails fit mid-scale shops and maintenance operations, while 55-gallon drums supply high-volume dry cleaners, production degreasers, and chemical processors.
Small Packs: UPS Ground nationwide for pints, quarts, and gallons.
LTL / FTL: ABF, SEFL, Saia, XPO, and partner carriers for pails, drums, totes, and full truckloads.
Support: Email or call for freight options, hazardous-material routing, and lead-time confirmation.

Product Overview

Perchloroethylene — also called PCE, PERC, or tetrachloroethylene — is a chlorinated solvent built for processes where water-based cleaning cannot perform. It dissolves greases, oils, waxes, and resins on contact without leaving moisture behind, which is why it became the default solvent in professional dry cleaning and industrial vapor degreasing. This technical grade product (CAS 127-18-4) is available from Alliance Chemical in sizes from 1-quart bottles through 55-gallon drums, serving operations from a single parts washer to a high-volume dry cleaning plant.

PCE is a Class 6.1 hazmat material (per 49 CFR 172.101). Every shipment from our Taylor, TX facility is classified, packaged, and documented by trained hazmat personnel under USDOT Registration #2188383.

Why This Grade

Technical grade perchloroethylene is the workhorse specification for production-scale solvent work — dry cleaning machines, closed-loop vapor degreasers, and immersion parts washers where the process demands a strong, fast-evaporating solvent rather than an analytical-purity reagent. Buyers selecting technical grade are purchasing for solvent performance at an industrial price point: the ability to cut through machining oils, forming compounds, and shop-floor contamination without water rinsing or drying steps.

If your application requires documented purity against a specific analytical standard, review the technical data sheet to verify the specification fits your process. For most metal degreasing, textile cleaning, and chemical-intermediate uses, technical grade delivers the performance these operations require.

Chemical Profile

Perchloroethylene (molecular formula C₂Cl₄, molecular weight 165.8) appears as a clear, colorless, volatile liquid with an ether-like odor. It is noncombustible — a significant handling advantage over many organic solvents. The liquid is dense: approximately 1.63 g/mL at 68 °F (about 13.5 lb per gallon), substantially heavier than water, meaning spilled PCE will sink rather than float. It is practically insoluble in water (less than 0.1 mg/mL at 63 °F), which is precisely why it excels in applications where moisture must be excluded. Its vapor pressure of 14 mmHg at 68 °F makes it moderately volatile at room temperature — enough to evaporate cleanly from parts, but not so volatile that it flashes off instantly. Vapors are heavier than air and will accumulate at floor level in enclosed spaces, a critical ventilation consideration for any operator.

Industrial Applications

PCE serves several distinct industrial workflows, each exploiting its combination of solvency, density, non-flammability, and rapid evaporation.

  • Metal degreasing. Vapor degreasing and immersion cleaning of machined, stamped, or fabricated metal parts. PCE dissolves cutting oils, drawing compounds, buffing residues, and flux without attacking the base metal. The solvent's non-flammability allows safe use in heated vapor degreasing equipment where flammable solvents would pose ignition risk.
  • Dry cleaning. The textile care industry relies on PCE to remove oil-based stains, body oils, and grease from fabrics that cannot tolerate water immersion. Closed-loop dry cleaning machines recover and recycle the solvent, and the technical grade specification suits this continuous-use cycle.
  • Chemical intermediate. PCE serves as a feedstock in the synthesis of fluorinated compounds and other chlorinated chemicals. Processors purchasing for this use typically require drum-scale quantities and consistent lot-to-lot composition.
  • Adhesive and sealant formulation. PCE acts as a carrier solvent in certain adhesive and sealant systems, dissolving polymeric binders before application and then evaporating cleanly from the bond line.

Handling & Storage

Perchloroethylene carries a Danger signal word (per the product's GHS classification). Operators must understand the hazard profile before opening a container.

Health hazards: PCE may cause drowsiness or dizziness from vapor inhalation (H336), causes skin irritation (H315) and may cause allergic skin reactions (H317), causes serious eye irritation (H319), is suspected of causing cancer (H351), causes damage to organs (H370), and may cause organ damage through prolonged or repeated exposure (H373) — all per the product's GHS classification. Work in well-ventilated areas or use local exhaust ventilation. Wear chemical-resistant gloves (butyl rubber or Viton recommended), splash-proof safety goggles, and a respirator rated for organic vapors when engineering controls are insufficient.

Environmental: Toxic to aquatic life with long-lasting effects (H411, per the product's GHS classification). Do not allow releases to drains, waterways, or soil. Dispose of waste solvent through a licensed hazardous waste hauler.

Storage: Keep containers tightly closed in a cool, dry, well-ventilated area away from heat sources and direct sunlight. Store away from strong oxidizing agents and strong acids. Use original containers or vessels made of compatible materials such as HDPE or glass. Because PCE is denser than water and heavier than air, ensure that storage areas have floor-level ventilation to prevent vapor accumulation.

Spill response: Vapors are heavier than air and will pool in low-lying areas. Evacuate the immediate area, ventilate, and contain the spill with inert absorbent. PCE sinks in water — do not attempt to flush spills with water into drains.

Hazmat & Shipping

Perchloroethylene is a regulated hazardous material for transport. Every shipment ships with proper DOT classification and documentation prepared by our trained hazmat team.

  • UN Number: UN1897 (per 49 CFR 172.101)
  • Proper Shipping Name: TETRACHLOROETHYLENE (per 49 CFR 172.101)
  • Hazard Class: 6.1 (Toxic) (per 49 CFR 172.101)
  • Packing Group: III (per 49 CFR 172.101)

All packaging — from quart bottles to 55-gallon drums — meets the applicable performance standards for this classification. Shipping documentation, including hazmat shipping papers and emergency response information, accompanies every order.

Documentation

A Safety Data Sheet (SDS) ships with every order. SDS documents are available in English, Spanish, French, and Japanese. A Technical Data Sheet (TDS) detailing product specifications is also available. Lot-specific Certificates of Analysis (COA) can be requested to verify composition against the specification for your incoming QC process.

Why Buy from Alliance Chemical

PCE is a Class 6.1 toxic material that demands correct classification, packaging, and documentation on every shipment — and Alliance Chemical has shipped hazmat chemicals from our Taylor, TX warehouse since 1998 under USDOT Registration #2188383. We offer this product in a range from quart bottles for bench-scale work to 55-gallon drums for production operations, so you order the quantity your process actually needs rather than adapting to a single container size.

Shipping and handling guidance on this page has been reviewed by Andre Taki, DOT Hazmat Specialist. Over 50,000 customers have purchased chemicals from Alliance Chemical — industrial buyers who need their solvent to arrive correctly classified, properly packaged, and with the right paperwork.

Frequently Asked Questions About Perchloroethylene (PCE, PERC)

What is Perchloroethylene (PCE, PERC) and what is its chemical formula?
Perchloroethylene (PCE, PERC) is listed under CAS 127-18-4 (PubChem reference search). The catalog formula is C2Cl4. The listed molecular weight is 165.8 g/mol. For solutions and blends, identity values may describe a constituent; consult the product SDS for composition.
What are the physical properties of Perchloroethylene (PCE, PERC)?
Catalog reference information for Perchloroethylene (PCE, PERC): form: Liquid; appearance: Colorless liquid with a mild, sweet odor; melting point: -2 °F (NTP, 1992); boiling point: 250 °F at 760 mmHg (NTP, 1992); flash point: No flash point in conventional closed tester.; specific gravity: 1.623; solubility: Slightly soluble in water, soluble in organic solvents; reference values may describe a pure substance rather than the supplied concentration or blend. Confirm applicable conditions and specifications in the product documents; these values are not batch test results.
What grade and purity of Perchloroethylene (PCE, PERC) does Alliance Chemical offer?
Alliance Chemical lists Perchloroethylene (PCE, PERC) in Technical Grade with a concentration or assay of 100%. Check the product specification for the measurement basis and acceptance limits. A grade label alone does not establish certification or suitability for a regulated application. For batch results, request a COA using the product name and lot number.
What are common industrial applications of Perchloroethylene (PCE, PERC)?
Catalog industry categories for Perchloroethylene (PCE, PERC) include Energy & Petroleum, Water & Environmental. To evaluate it for your process, compare the listed grade, concentration and product specifications with your requirements. Contact Alliance Chemical to confirm any application-specific documentation or certification before ordering.
What are the hazards of Perchloroethylene (PCE, PERC) and where do I find handling guidance?
Per its GHS classification (SDS Section 2), Perchloroethylene (PCE, PERC) carries the signal word Warning and the following hazard statements: H315 CAUSES SKIN IRRITATION; H317 MAY CAUSE AN ALLERGIC SKIN REACTION; H319 CAUSES SERIOUS EYE IRRITATION; H336 MAY CAUSE DROWSINESS OR DIZZINESS; H351 SUSPECTED OF CAUSING CANCER; H370 CAUSES DAMAGE TO ORGANS; H373 MAY CAUSE DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE; H411 TOXIC TO AQUATIC LIFE WITH LONG LASTING EFFECTS. Product-specific first aid, fire-fighting, spill response, handling, storage, exposure controls/PPE, and disposal guidance are in SDS Sections 4-8 and 13 — always consult the SDS before use. Download the SDS.
What is the DOT shipping classification for Perchloroethylene (PCE, PERC)?
The catalog transport entry lists UN1897, hazard class 6.1, packing group III. Consult SDS Section 14 and confirm the requirements for your selected pack size and shipping destination with Alliance Chemical.
How must Perchloroethylene (PCE, PERC) waste be disposed?
Consult SDS Section 13 for disposal information for Perchloroethylene (PCE, PERC). Disposal requirements depend on the resulting waste, contamination and location. Have your site's responsible waste professional determine the appropriate waste classification and disposal method. View the SDS.
Does Alliance Chemical provide an SDS and COA for Perchloroethylene (PCE, PERC)?
Search the document library for Perchloroethylene (PCE, PERC). The SDS is also available here. A sample COA describes specifications and does not establish the results for your shipment. To request a lot-specific COA or confirm document availability, contact Alliance Chemical with the product name and lot number.