Ethylene Glycol Inhibited ACS Grade

Category : Glycols

$29.77
Quantity
Size:
Variation:
  • $22.94
    Delivery every
    $21.79
  • $29.77
    Delivery every
    $28.28
  • $39.92
    Delivery every
    $37.92
  • $55.64
    Delivery every
    $52.86
  • $39.92
    Delivery every
    $37.92
  • $55.64
    Delivery every
    $52.86
  • $105.79
    Delivery every
    $100.50
  • $2,979.05
    Delivery every
    $2,830.10
  • $135.51
    Delivery every
    $128.73
  • $498.67
    Delivery every
    $473.74
  • $3,652.66
    Delivery every
    $3,470.03
  • $377.78
    Delivery every
    $358.89
  • $1,149.32
    Delivery every
    $1,091.85
  • $3,652.66
    Delivery every
    $3,470.03
  • $4,206.74
    Delivery every
    $3,996.40
  • $4,644.24
    Delivery every
    $4,412.03
Other Grades & Concentrations

Available in other grades and concentrations:

Ethylene Glycol Semiconductor Grade
From $15.52
CAS: 107-21-1 C2H6O2
Ethylene Glycol ACS Grade
From $22.94
CAS: 107-21-1 C2H6O2
100% Ethylene Glycol Inhibited
From $21.35
CAS: 107-21-1 C2H6O2
Ethylene Glycol 60/40
From $19.80
CAS: 107-21-1 C2H6O2
$29.77
Other Grades & Concentrations

Available in other grades and concentrations:

Ethylene Glycol Semiconductor Grade
From $15.52
CAS: 107-21-1 C2H6O2
Ethylene Glycol ACS Grade
From $22.94
CAS: 107-21-1 C2H6O2
100% Ethylene Glycol Inhibited
From $21.35
CAS: 107-21-1 C2H6O2
Ethylene Glycol 60/40
From $19.80
CAS: 107-21-1 C2H6O2

Ethylene Glycol Inhibited ACS Grade

$29.77

Commercial Fulfillment Snapshot

Buy Ethylene Glycol Inhibited ACS Grade with faster decisions and fewer back-and-forth emails.

Ships from Taylor, Texas. In-stock orders placed before 1:00 PM CT (Mon-Thu) and before 12:00 PM CT (Fri) typically ship same business day. Order online 24/7.

Technical Documents

Lot-specific COA is issued per shipment batch.

Who Buys This
  • Analytical chemistry laboratories
  • Research & development facilities
  • Quality control departments
  • Pharmaceutical testing labs
  • University chemistry programs
Purity / Grade Guide
  • ACS Grade analytical applications
  • Laboratory research & testing
  • High-purity inhibited formula
  • COA verifies specifications
Pack Sizes
  • 1 Quart: lab & small jobs
  • 1 Gallon: shop & maintenance
  • 5 Gallon: production & regular use
  • 15 Gallon: mid-volume operations
  • 55 Gallon: bulk drum
  • 275 Gallon: high-volume tote
  • 330 Gallon: max-volume tote
SDS / COA / TDS
  • SDS safety data sheet
  • COA certificate of analysis
  • UN 3082 Class 9 packaging
  • ACS grade documentation
Small Packs: UPS Ground nationwide for pints, quarts, and gallons.
LTL / FTL: ABF, SEFL, Saia, XPO, and partner carriers for pails, drums, totes, and full truckloads.
Support: Email or call for freight options, hazardous-material routing, and lead-time confirmation.

Why Ethylene Glycol Inhibited ACS Grade

Ethylene Glycol Inhibited ACS Grade combines the strict analytical purity of an American Chemical Society laboratory standard with built-in corrosion inhibitors to support demanding industrial and research environments. At a 100% concentration, this clear, colorless viscous liquid with a flash point of 111 requires site-specific dilution with water to achieve an optimal freeze protection curve. While pure C2H6O2 freezes around 10°F, blending it with water drops the freezing point significantly, allowing operators to dial in the exact ratio needed for specific climate conditions. The integrated inhibitors actively protect closed-loop metal systems from rust, scale, and long-term degradation.

Best Applications for This Grade

  • Commonly applied in research and analytical laboratories where strict ACS purity guarantees baseline consistency for chemical testing, while the included inhibitors protect the internal metal components of laboratory cooling apparatuses.
  • Commonly applied in heavy industrial closed-loop cooling and HVAC systems where facilities operators must custom-blend their own water ratios from a 100% concentrate to match precise local winter freeze protection requirements.
  • Commonly applied in wastewater treatment infrastructure to maintain temperature stability in external piping networks, utilizing the product's full miscibility with water and polar organic solvents to prevent fluid crystallization.
  • Commonly applied in mixed-metal industrial heat transfer systems, where the integrated corrosion inhibitors actively prevent galvanic corrosion and pitting across iron, copper, and brass system components.

When to Choose a Different Grade

  • If the facility requires a pre-mixed solution ready for immediate system charging without the labor of on-site dilution, choose Ethylene Glycol 50/50 for standard operational freeze protection or Ethylene Glycol 60/40 for severe cold weather climates.
  • If the operation requires an uninhibited, pure baseline chemical without anti-corrosion additives for sensitive chemical reactions or standardizations, choose Ethylene Glycol ACS Grade.
  • If the project demands bulk commercial heat transfer capabilities without the strict analytical purity controls of an ACS laboratory standard, choose 100% Ethylene Glycol Inhibited.
  • If the process involves microchip fabrication or delicate electronics manufacturing requiring ultra-low trace metals and particulate counts, choose Ethylene Glycol Semiconductor Grade.
Property Value
Molecular Weight 62.07
Formula C2H6O2
Assay 99-100.5%
Grade ACS Grade
Flash Point 111°C (231.8°F)
Form Liquid
Solubility Miscible with water and many organic solvents
Appearance Colorless, viscous liquid
Melting Point -12.9
Boiling Point 197.6
Specific Gravity 1.113
Industry Automotive, Industrial, Chemical Manufacturing, Manufacturing, Pharmaceutical

Frequently Asked Questions About Ethylene Glycol Inhibited ACS Grade

What is Ethylene Glycol Inhibited ACS Grade and what is its chemical formula?
Ethylene Glycol Inhibited ACS Grade is a chemical compound with the molecular formula C2H6O2, registered under CAS Number 107-21-1 by the Chemical Abstracts Service (PubChem), with a molecular weight of 62.07 g/mol. Alliance Chemical supplies Ethylene Glycol Inhibited ACS Grade in ACS Reagent grade for laboratory, industrial, and commercial applications.
What are the physical properties of Ethylene Glycol Inhibited ACS Grade?
According to the NIOSH Pocket Guide to Chemical Hazards, Ethylene Glycol Inhibited ACS Grade is supplied as a clear, colorless viscous liquid. It has a melting point of -13°C (8.6°F)°C, a boiling point of 197°C (386.6°F)°C, a flash point of 111°C (231.8°F). The specific gravity is 1.113 relative to water. Solubility: Fully miscible with water, polar organic solvents.
What grade and purity of Ethylene Glycol Inhibited ACS Grade does Alliance Chemical offer?
Alliance Chemical offers Ethylene Glycol Inhibited ACS Grade in ACS Reagent grade with a purity assay of 100%. Every lot ships with a Certificate of Analysis (COA) and Safety Data Sheet (SDS) prepared in accordance with OSHA Hazard Communication Standard 29 CFR 1910.1200 and GHS Revision 7. Download SDS.
What are common industrial applications of Ethylene Glycol Inhibited ACS Grade?
Ethylene Glycol Inhibited ACS Grade serves a wide range of sectors, including Industrial & Manufacturing, Lab & Research, and Water & Environmental.Alliance Chemical provides the documentation and quality certifications required for use in regulated environments.
What PPE is required when handling Ethylene Glycol Inhibited ACS Grade?
OSHA-mandated PPE per 29 CFR 1910.132-138:Nitrile gloves (8+ mil), safety goggles, flame-resistant clothing, grounded footwear, closed-toe chemical-resistant footwear. Respiratory protection (organic vapor cartridge) required in areas exceeding PEL/TLV per 29 CFR 1910.134. Emergency eyewash station and safety shower must be accessible within 10 seconds per ANSI Z358.1. Consult the SDS available from Alliance Chemical for complete PPE requirements.
What are the storage requirements for Ethylene Glycol Inhibited ACS Grade?
Store perOSHA 29 CFR 1910.106: Approved flammable storage cabinet, maximum 60 gallons per cabinet, grounding/bonding required. Temperature range:15-25°C. Segregate from:oxidizers, ignition sources. Maximum storage:2-3 years unopened.
What is the emergency spill procedure for Ethylene Glycol Inhibited ACS Grade?
Emergency response per EPA SPCC (40 CFR 112) and OSHA 29 CFR 1910.120: (1) Alert personnel, evacuate area to 100 feet. (2) Eliminate ignition sources if flammable. (3) Don PPE per SDS Section 8. (4) Stop leak if safe; use emergency shutoffs. (5) Contain with non-combustible absorbent materials, dike with sand/earth. (6)Absorb with vermiculite or commercial spill kits. (7) Collect in DOT-approved containers, label as hazardous waste. Check 40 CFR 302.4 for Reportable Quantity. Emergency: Chemtel 1-800-255-3924 (24/7). Non-emergency: Alliance Chemical 512-365-6838.
What is the DOT shipping classification for Ethylene Glycol Inhibited ACS Grade?
DOT Classification per 49 CFR 172.101:UN3082, Hazard Class9, Packing GroupIII. Requires: Hazmat shipping papers (49 CFR 172.200), UN specification packaging (49 CFR 173), hazmat labels (172.400). Alliance Chemical ships all orders in DOT-compliant packaging with proper documentation.
How must Ethylene Glycol Inhibited ACS Grade waste be disposed?
Disposal per RCRA (40 CFR 261-265):Characteristic waste D001 (Ignitable, flash point <60°C). Generator requirements: EPA ID number required if >100 kg/month (40 CFR 262.12). Use EPA-permitted Treatment, Storage, Disposal Facility (TSDF). Never discharge to sewer without POTW written approval (40 CFR 403). Container disposal: Triple rinse (40 CFR 261.7), offer for reconditioning/recycling. State regulations may be more stringent — check with your local environmental agency. Consult the Alliance Chemical SDS for product-specific disposal guidance.
Does Alliance Chemical provide an SDS and COA for Ethylene Glycol Inhibited ACS Grade?
Yes. Alliance Chemical provides a Safety Data Sheet (SDS) and Certificate of Analysis (COA) for every lot of Ethylene Glycol Inhibited ACS Grade. The SDS is prepared in accordance with OSHA Hazard Communication Standard 29 CFR 1910.1200 and the Globally Harmonized System (GHS) Revision 7, covering all 16 required sections including hazard identification, first aid measures, firefighting measures, handling and storage, exposure controls, and regulatory information. The SDS is available for download directly from this product page. COAs are available upon request by contacting Alliance Chemical at 512-365-6838.