Product Overview

Arctic Assist 50/50 is a specialized heat transfer fluid and antifreeze engineered for thermal stability in industrial and commercial environments. Formulated for cold-weather operation, it maintains flow characteristics at low temperatures while protecting systems from freezing. This solution is essential for chillers, process cooling loops, and closed-system HVAC applications requiring consistent thermal conductivity.

The fluid appears as a clear, colorless liquid with a density of 1.025 g/mL at 25°C. With a freezing point of -10°C and a boiling range of 100-110°C, Arctic Assist 50/50 ensures operational integrity in climate-controlled or exposed systems. Its moderate vapor pressure supports stable performance in semi-closed setups where evaporation control is critical. Compatible with HDPE storage and standard piping materials, it offers a reliable solution for facility managers and plant engineers.

 

Key Properties

  • Appearance: Clear, colorless liquid
  • CAS Number: 64742-47-8
  • Boiling Point: 100-110°C
  • Freezing Point: -10°C
  • Density (25°C): 1.025 g/mL
  • Specific Gravity (25°C): 1.02–1.03
  • pH (25°C): 6.5–7.5
  • Viscosity (25°C): 1.2 cP
  • Vapor Pressure (20°C): 15 mmHg

 

Common Applications

  • Process Cooling: Primary coolant for industrial chillers and manufacturing heat exchange systems.
  • HVAC Systems: Heat transfer medium for closed-loop heating and cooling circuits.
  • Cold Storage: Thermal fluid for maintaining controlled low temperatures in refrigeration units.
  • Equipment Protection: Prevents freezing and bursting of pipes in exposed industrial machinery.

 

Safety Precautions

Handle Arctic Assist 50/50 using appropriate personal protective equipment (PPE), including chemical-resistant gloves and safety goggles. Use in well-ventilated areas to avoid accumulation of vapors. Store in original HDPE containers in a cool, dry location away from direct sunlight and strong oxidizing agents.

Refer to the Safety Data Sheet (SDS) for detailed spill response, first aid procedures, and disposal guidelines. Verify compatibility with system seals, gaskets, and metals prior to introduction into the process loop.

 

Related Products

Property Value
Molecular Weight 170.33 g/mol
Formula C12H26
Assay 50%%
Flash Point 62
Form Liquid
Solubility Moderate organic solvent solubility
Appearance pink dyed liquid, low viscosity
Melting Point -9 °C
Boiling Point 165 °C
Specific Gravity 1.045
Industry Industrial, Environmental, Research

Frequently Asked Questions About Arctic Assist 50/50

What is Arctic Assist 50/50 and what is its chemical formula?
Arctic Assist 50/50 is a chemical compound with the molecular formula C12H26, registered under CAS Number 64742-47-8 by the Chemical Abstracts Service (PubChem), with a molecular weight of 170.33 g/mol. Alliance Chemical supplies Arctic Assist 50/50 for laboratory, industrial, and commercial applications.
What are the physical properties of Arctic Assist 50/50?
According to the NIOSH Pocket Guide to Chemical Hazards, Arctic Assist 50/50 is supplied as a pink dyed liquid, low viscosity. It has a melting point of -9°C, a boiling point of 165°C, a flash point of 62. The specific gravity is 1.045 relative to water. Solubility: Moderate organic solvent solubility.
What grade and purity of Arctic Assist 50/50 does Alliance Chemical offer?
Alliance Chemical offers Arctic Assist 50/50 with a purity assay of 50%. Every lot ships with a Certificate of Analysis (COA) and Safety Data Sheet (SDS) prepared in accordance with OSHA Hazard Communication Standard 29 CFR 1910.1200 and GHS Revision 7. Download SDS.
What are common industrial applications of Arctic Assist 50/50?
Arctic Assist 50/50 serves a wide range of sectors, including Industrial, Environmental, and Research.Alliance Chemical provides the documentation and quality certifications required for use in regulated environments.
What PPE is required when handling Arctic Assist 50/50?
OSHA-mandated PPE per 29 CFR 1910.132-138:Nitrile gloves (8+ mil), safety goggles, flame-resistant clothing, grounded footwear, closed-toe chemical-resistant footwear. Respiratory protection (organic vapor cartridge) required in areas exceeding PEL/TLV per 29 CFR 1910.134. Emergency eyewash station and safety shower must be accessible within 10 seconds per ANSI Z358.1. Consult the SDS available from Alliance Chemical for complete PPE requirements.
What are the storage requirements for Arctic Assist 50/50?
Store perOSHA 29 CFR 1910.106: Approved flammable storage cabinet, maximum 60 gallons per cabinet, grounding/bonding required. Temperature range:15-25°C. Segregate from:oxidizers, ignition sources. Maximum storage:2-3 years unopened.
What is the emergency spill procedure for Arctic Assist 50/50?
Emergency response per EPA SPCC (40 CFR 112) and OSHA 29 CFR 1910.120: (1) Alert personnel, evacuate area to 100 feet. (2) Eliminate ignition sources if flammable. (3) Don PPE per SDS Section 8. (4) Stop leak if safe; use emergency shutoffs. (5) Contain with non-combustible absorbent materials, dike with sand/earth. (6)Absorb with vermiculite or commercial spill kits. (7) Collect in DOT-approved containers, label as hazardous waste. Check 40 CFR 302.4 for Reportable Quantity. Emergency: Chemtel 1-800-255-3924 (24/7). Non-emergency: Alliance Chemical 512-365-6838.
What is the DOT shipping classification for Arctic Assist 50/50?
DOT Classification per 49 CFR 172.101:UN1993 (Flammable Liquid, N.O.S.), Hazard Class3 (Flammable), Packing GroupII/III. Requires: Hazmat shipping papers (49 CFR 172.200), UN specification packaging (49 CFR 173), hazmat labels (172.400). Alliance Chemical ships all orders in DOT-compliant packaging with proper documentation.
How must Arctic Assist 50/50 waste be disposed?
Disposal per RCRA (40 CFR 261-265):Characteristic waste D001 (Ignitable, flash point <60°C). Generator requirements: EPA ID number required if >100 kg/month (40 CFR 262.12). Use EPA-permitted Treatment, Storage, Disposal Facility (TSDF). Never discharge to sewer without POTW written approval (40 CFR 403). Container disposal: Triple rinse (40 CFR 261.7), offer for reconditioning/recycling. State regulations may be more stringent — check with your local environmental agency. Consult the Alliance Chemical SDS for product-specific disposal guidance.
Does Alliance Chemical provide an SDS and COA for Arctic Assist 50/50?
Yes. Alliance Chemical provides a Safety Data Sheet (SDS) and Certificate of Analysis (COA) for every lot of Arctic Assist 50/50. The SDS is prepared in accordance with OSHA Hazard Communication Standard 29 CFR 1910.1200 and the Globally Harmonized System (GHS) Revision 7, covering all 16 required sections including hazard identification, first aid measures, firefighting measures, handling and storage, exposure controls, and regulatory information. The SDS is available for download directly from this product page. COAs are available upon request by contacting Alliance Chemical at 512-365-6838.