Battery Water

Category : Inorganic Compounds

$22.00
Quantity
Size:
Variation:
  • $22.00
    Delivery every
    $20.90
  • $25.00
    Delivery every
    $23.75
  • $29.50
    Delivery every
    $28.03
  • $39.00
    Delivery every
    $37.05
  • $29.50
    Delivery every
    $28.03
  • $39.00
    Delivery every
    $37.05
  • $59.00
    Delivery every
    $56.05
  • $1,270.08
    Delivery every
    $1,206.58
  • $73.01
    Delivery every
    $69.36
  • $286.23
    Delivery every
    $271.92
  • $1,350.00
    Delivery every
    $1,282.50
  • $216.84
    Delivery every
    $206.00
  • $490.00
    Delivery every
    $465.50
  • $1,350.00
    Delivery every
    $1,282.50
  • $1,560.00
    Delivery every
    $1,482.00
  • $1,722.24
    Delivery every
    $1,636.13
$22.00

Battery Water

$22.00

Commercial Fulfillment Snapshot

Buy Battery Water with faster decisions and fewer back-and-forth emails.

Ships from Taylor, Texas. In-stock orders placed before 1:00 PM CT (Mon-Thu) and before 12:00 PM CT (Fri) typically ship same business day. Order online 24/7.

Technical Documents

Lot-specific COA is issued per shipment batch.

Who Buys This
  • Automotive service centers
  • Battery maintenance companies
  • Industrial equipment operators
  • Research laboratories
  • Hydroponic growers
Purity / Grade Guide
  • Industrial & lab applications
  • Deionized & distilled purity
  • 99.9% minimum assay verified
  • Low mineral content guaranteed
Pack Sizes
  • 1 Quart: lab & small jobs
  • 1 Gallon: shop & maintenance
  • 5 Gallon: production & regular use
  • 15 Gallon: mid-volume operations
  • 55 Gallon: bulk drum
  • 275 Gallon: high-volume tote
  • 330 Gallon: max-volume tote
SDS / COA / TDS
  • Non-regulated ground shipment
  • Certificate of Analysis included
  • Safety Data Sheet provided
  • Same-day shipping before 1PM
Small Packs: UPS Ground nationwide for pints, quarts, and gallons.
LTL / FTL: ABF, SEFL, Saia, XPO, and partner carriers for pails, drums, totes, and full truckloads.
Support: Email or call for freight options, hazardous-material routing, and lead-time confirmation.

Product Overview

Alliance Chemical Battery Water is a , highly purified deionized water designed for critical electrochemical applications. Unlike standard distilled water, this product is processed to remove ionic impurities, minerals, and dissolved solids that cause scaling and reduce the efficiency of lead-acid battery systems. It meets strict specifications for low conductivity and minimal trace metals.

Industrial buyers rely on this high-purity water for maintaining forklift batteries, backup power systems, and golf cart fleets, where water quality directly impacts battery cycle life. Beyond battery maintenance, it serves as a reliable solvent for laboratory reagents, cooling system flush fluids, and industrial rinsing applications. Available in bulk sizes from 5-gallon pails to 330-gallon totes, it offers a scalable solution for facility managers and process engineers.

Key Properties

  • Product: Battery Water (Deionized)
  • CAS Number: 7732-18-5
  • Appearance: Clear, colorless liquid
  • Assay (Purity): 99.9% - 100.0%
  • Specific Gravity: 0.998 – 1.000
  • Residue After Ignition: ≤ 0.01%
  • Chloride: ≤ 5 ppm
  • Nitrate (NO₃⁻): ≤ 0.5 ppm
  • Sulfate (SO₄²⁻): ≤ 5 ppm
  • Heavy Metals (as Pb): ≤ 0.005 ppm
  • Iron (Fe): ≤ 0.1 ppm
  • Conductivity: Ultra-low (High resistivity)

Common Applications

  • Lead-Acid Battery Maintenance: Essential for refilling industrial forklift, marine, and motive power batteries. Prevents plate scaling and preserves electrolyte specific gravity.
  • Laboratory Solvent: Used as a universal solvent and diluent in analytical chemistry and reagent preparation where ionic interference must be minimized.
  • Industrial Cooling Systems: Utilized in closed-loop cooling circuits and heat exchangers to prevent mineral deposits and corrosion.
  • Electroplating & Metal Finishing: Provides a neutral, contaminant-free rinse water to prevent spotting and ensure coating adhesion.
  • Chemical Formulation: Acts as a high-purity base for aqueous chemical products and critical cleaning solutions.

Safety & Handling

While Battery Water is non-hazardous and non-toxic, standard industrial hygiene practices should be observed to maintain product purity. Store in a cool, dry area away from direct sunlight. Keep containers tightly sealed when not in use to prevent absorption of carbon dioxide or airborne particulates which can alter conductivity.

Storage: Use original HDPE containers or dedicated high-purity water tanks to prevent leaching. Avoid contact with strong dehydrating agents or materials that react violently with water.
Spill Control: Spilled water may create a slipping hazard. Clean up immediately. No special disposal mandates are required for the water itself, though local regulations regarding wastewater discharge should always be followed.

Related Products

Property Value
Molecular Weight 18.02 g/mol
Formula H2O
Flash Point Not applicable
Form Liquid
Solubility Soluble in water
Appearance Clear, colorless liquid
Melting Point 0 °C
Boiling Point 100 °C
Specific Gravity 1.0
Industry Industrial, Wastewater, Power Systems

Frequently Asked Questions About Battery Water

What is Battery Water and what is its chemical formula?
Battery Water is a chemical compound with the molecular formula H2O, registered under CAS Number 7732-18-5 by the Chemical Abstracts Service (PubChem), with a molecular weight of 18.02 g/mol. Alliance Chemical supplies Battery Water for laboratory, industrial, and commercial applications.
What are the physical properties of Battery Water?
According to the NIOSH Pocket Guide to Chemical Hazards, Battery Water is supplied as a clear, colorless liquid. It has a melting point of 0°C, a boiling point of 100°C, a flash point of Not applicable. The specific gravity is 1.0 relative to water. Solubility: Soluble in water.
What are common industrial applications of Battery Water?
Battery Water serves a wide range of sectors, including Industrial, Wastewater, and Power Systems.Alliance Chemical provides the documentation and quality certifications required for use in regulated environments.
What PPE is required when handling Battery Water?
OSHA-mandated PPE per 29 CFR 1910.132-138:Nitrile gloves (8+ mil), safety goggles, flame-resistant clothing, grounded footwear, closed-toe chemical-resistant footwear. Respiratory protection (organic vapor cartridge) required in areas exceeding PEL/TLV per 29 CFR 1910.134. Emergency eyewash station and safety shower must be accessible within 10 seconds per ANSI Z358.1. Consult the SDS available from Alliance Chemical for complete PPE requirements.
What are the storage requirements for Battery Water?
Store perOSHA 29 CFR 1910.106: Approved flammable storage cabinet, maximum 60 gallons per cabinet, grounding/bonding required. Temperature range:15-25°C. Segregate from:oxidizers, ignition sources. Maximum storage:2-3 years unopened.
What is the emergency spill procedure for Battery Water?
Emergency response per EPA SPCC (40 CFR 112) and OSHA 29 CFR 1910.120: (1) Alert personnel, evacuate area to 100 feet. (2) Eliminate ignition sources if flammable. (3) Don PPE per SDS Section 8. (4) Stop leak if safe; use emergency shutoffs. (5) Contain with non-combustible absorbent materials, dike with sand/earth. (6)Absorb with vermiculite or commercial spill kits. (7) Collect in DOT-approved containers, label as hazardous waste. Check 40 CFR 302.4 for Reportable Quantity. Emergency: Chemtel 1-800-255-3924 (24/7). Non-emergency: Alliance Chemical 512-365-6838.
What is the DOT shipping classification for Battery Water?
DOT Classification per 49 CFR 172.101:UN1993 (Flammable Liquid, N.O.S.), Hazard Class3 (Flammable), Packing GroupII/III. Requires: Hazmat shipping papers (49 CFR 172.200), UN specification packaging (49 CFR 173), hazmat labels (172.400). Alliance Chemical ships all orders in DOT-compliant packaging with proper documentation.
How must Battery Water waste be disposed?
Disposal per RCRA (40 CFR 261-265):Characteristic waste D001 (Ignitable, flash point <60°C). Generator requirements: EPA ID number required if >100 kg/month (40 CFR 262.12). Use EPA-permitted Treatment, Storage, Disposal Facility (TSDF). Never discharge to sewer without POTW written approval (40 CFR 403). Container disposal: Triple rinse (40 CFR 261.7), offer for reconditioning/recycling. State regulations may be more stringent — check with your local environmental agency. Consult the Alliance Chemical SDS for product-specific disposal guidance.
Does Alliance Chemical provide an SDS and COA for Battery Water?
Yes. Alliance Chemical provides a Safety Data Sheet (SDS) and Certificate of Analysis (COA) for every lot of Battery Water. The SDS is prepared in accordance with OSHA Hazard Communication Standard 29 CFR 1910.1200 and the Globally Harmonized System (GHS) Revision 7, covering all 16 required sections including hazard identification, first aid measures, firefighting measures, handling and storage, exposure controls, and regulatory information. The SDS is available for download directly from this product page. COAs are available upon request by contacting Alliance Chemical at 512-365-6838.