30% Propylene Glycol Inhibited

Category : Glycols

$21.63
Quantity
Size:
Variation:
Other Grades & Concentrations

Available in other grades and concentrations:

CAS: 57-55-6 C3H8O2
Propylene Glycol USP Grade
From $26.45
CAS: 57-55-6 C3H8O2
Propylene Glycol 60% USP Grade
From $19.00
CAS: 57-55-6 C3H8O2
CAS: 57-55-6 50% C3H8O2 / 50% H2O
$21.63
Other Grades & Concentrations

Available in other grades and concentrations:

CAS: 57-55-6 C3H8O2
Propylene Glycol USP Grade
From $26.45
CAS: 57-55-6 C3H8O2
Propylene Glycol 60% USP Grade
From $19.00
CAS: 57-55-6 C3H8O2
CAS: 57-55-6 50% C3H8O2 / 50% H2O

30% Propylene Glycol Inhibited

$21.63

Commercial Fulfillment Snapshot

Buy 30% Propylene Glycol Inhibited with faster decisions and fewer back-and-forth emails.

Ships from Taylor, Texas. In-stock orders placed before 1:00 PM CT (Mon-Thu) and before 12:00 PM CT (Fri) typically ship same business day. Order online 24/7.

Technical Documents

Lot-specific COA is issued per shipment batch.

Who Buys This
  • Automotive
  • Industrial
  • Manufacturing
  • Food and Beverage
  • Pharmaceutical
Purity / Grade Guide
  • Technical Gradefor commercial purchasing
  • 29-31% concentration / assay target
  • Lot-specific COA available with shipment; TDS published
Pack Sizes
  • 1 Quart
  • 1 Gallon
  • 5 Gallon
  • 15 Gallon
  • 55 Gallon
  • 275 Gallon
  • 330 Gallon
SDS / COA / TDS
  • SDS available for immediate download
  • TDS available for specification review
  • COA available by shipment batch
  • Class ified
Small Packs: UPS Ground nationwide for pints, quarts, and gallons.
LTL / FTL: ABF, SEFL, Saia, XPO, and partner carriers for pails, drums, totes, and full truckloads.
Support: Email or call for freight options, hazardous-material routing, and lead-time confirmation.

Why 30% Propylene Glycol Inhibited

30% Propylene Glycol Inhibited delivers a pre-mixed, low-toxicity heat transfer fluid designed specifically for systems requiring moderate freeze protection alongside active metal protection. The built-in heavy-duty corrosion inhibitors safeguard closed-loop circuits against rust, scaling, and degradation, extending the operational life of internal pipes, valves, and pumps. Over time, uninhibited fluids naturally degrade into organic acids that attack system metals. The specialized inhibitor package in this formulation actively buffers the pH, preventing acid formation and protecting diverse system materials including copper, brass, steel, and cast iron. By selecting a pre-mixed 30% concentration, facility managers eliminate on-site dilution variables and poor local water quality risks, ensuring an immediate, accurate system charge for environments with mild winter conditions. This low-toxicity profile provides a safer operational alternative to traditional highly toxic fluid options within industrial settings, mitigating environmental impact during routine maintenance.

Best Applications for This Grade

  • Commonly applied in HVAC closed-loop hydronic heating and cooling systems where baseline freeze and burst protection is required alongside multi-metal corrosion control.
  • Commonly applied in secondary heat transfer circuits and heavy-duty chiller systems operating in facilities that do not experience extreme sub-zero temperatures, maintaining efficient fluid flow and thermal stability.
  • Commonly applied in industrial heat extraction processes and manufacturing plants where a low-toxicity heat transfer fluid is mandatory to protect personnel, provided direct food contact is not a factor.
  • Commonly applied in large-scale solar thermal arrays and commercial radiant floor heating networks to maintain consistent volume efficiency while actively preventing scale buildup on heat exchanger surfaces.

When to Choose a Different Grade

  • If your system operates in colder climates requiring deeper freeze and burst protection across extreme temperature drops, adjust your operating curve by selecting 40% Propylene Glycol Inhibited or 50% Propylene Glycol Inhibited.
  • If you manage a facility in severe northern climates requiring specialized maximum freeze point suppression, or if you maintain heavy equipment requiring precise custom dosing with deionized water, choose 60/40 Propylene Glycol Inhibited or 100% Propylene Glycol Inhibited.
  • If your industrial process requires an uninhibited base chemical for custom heat transfer formulation or facility-specific inhibitor packages, choose 30% Propylene Glycol Technical Grade.
Property Value
Molecular Weight 76.09
Assay 29-31%
Grade Technical
Form Liquid
Solubility Miscible in water and many organic solvents
Appearance Clear, colorless liquid
Melting Point -59
Boiling Point 188.2
Specific Gravity 1.036
Industry Automotive, Industrial, Manufacturing, Food and Beverage, Pharmaceutical

Frequently Asked Questions About 30% Propylene Glycol Inhibited

What is 30% Propylene Glycol Inhibited and what is its chemical formula?
30% Propylene Glycol Inhibited is a chemical compound. Alliance Chemical supplies 30% Propylene Glycol Inhibited in Technical grade for laboratory, industrial, and commercial applications.
What grade and purity of 30% Propylene Glycol Inhibited does Alliance Chemical offer?
Alliance Chemical offers 30% Propylene Glycol Inhibited in Technical grade with a purity assay of 30%. Every lot ships with a Certificate of Analysis (COA) and Safety Data Sheet (SDS) prepared in accordance with OSHA Hazard Communication Standard 29 CFR 1910.1200 and GHS Revision 7. Download SDS.
What are common industrial applications of 30% Propylene Glycol Inhibited?
30% Propylene Glycol Inhibited has applications in laboratory research, manufacturing, and industrial processing.Alliance Chemical provides the documentation and quality certifications required for use in regulated environments.
What PPE is required when handling 30% Propylene Glycol Inhibited?
OSHA-mandated PPE per 29 CFR 1910.132-138:Chemical-resistant gloves (nitrile/neoprene), safety goggles, lab coat, closed-toe chemical-resistant footwear. Emergency eyewash station and safety shower must be accessible within 10 seconds per ANSI Z358.1. Consult the SDS available from Alliance Chemical for complete PPE requirements.
What are the storage requirements for 30% Propylene Glycol Inhibited?
Store perOSHA standards: Cool, dry, ventilated area. Temperature range:15-25°C. Segregate from:incompatible materials per SDS Section 10. Maximum storage:2-3 years unopened.
What is the emergency spill procedure for 30% Propylene Glycol Inhibited?
Emergency response per EPA SPCC (40 CFR 112) and OSHA 29 CFR 1910.120: (1) Alert personnel, evacuate area to 50 feet. (2) Eliminate ignition sources if flammable. (3) Don PPE per SDS Section 8. (4) Stop leak if safe; use emergency shutoffs. (5) Contain with non-combustible absorbent materials, dike with sand/earth. (6)Absorb with vermiculite or commercial spill kits. (7) Collect in DOT-approved containers, label as hazardous waste. Check 40 CFR 302.4 for Reportable Quantity. Emergency: Chemtel 1-800-255-3924 (24/7). Non-emergency: Alliance Chemical 512-365-6838.
How must 30% Propylene Glycol Inhibited waste be disposed?
Disposal per RCRA (40 CFR 261-265):Evaluate per 40 CFR 261. Generator requirements: EPA ID number required if >100 kg/month (40 CFR 262.12). Use EPA-permitted Treatment, Storage, Disposal Facility (TSDF). Never discharge to sewer without POTW written approval (40 CFR 403). Container disposal: Triple rinse (40 CFR 261.7), offer for reconditioning/recycling. State regulations may be more stringent — check with your local environmental agency. Consult the Alliance Chemical SDS for product-specific disposal guidance.
Does Alliance Chemical provide an SDS and COA for 30% Propylene Glycol Inhibited?
Yes. Alliance Chemical provides a Safety Data Sheet (SDS) and Certificate of Analysis (COA) for every lot of 30% Propylene Glycol Inhibited. The SDS is prepared in accordance with OSHA Hazard Communication Standard 29 CFR 1910.1200 and the Globally Harmonized System (GHS) Revision 7, covering all 16 required sections including hazard identification, first aid measures, firefighting measures, handling and storage, exposure controls, and regulatory information. The SDS is available for download directly from this product page. COAs are available upon request by contacting Alliance Chemical at 512-365-6838.